Authentication

The first page requests authentication. The default password
for access is gefransetup.
Press the login button to send the password.
If the password is not sent within 30 seconds, the terminal
reboots. Time is shown by a colored bar at the top of the
page.
After authentication, the main menu appears:
Select the item required to access the submenu. Exit quits
the setup program and reboots the system.
24

Configuration

Here you can set the date and time, change the password,
set network parameters, manage remote communications,
configure the touchscreen, and configure the SNTP/ NTP
Server.
Press Home to return to the main menu.
Date and Time
To change a data item, touch the item in question with your
finger. A number pad appears.
Enter the new item and confirm with on OK, or cancel the
operation with CANCEL.
Password
To change the password for access to the setup program,
press the Password. The following page appears:
Touch the screen on the new password box.
An alphameric pad appears.
The new password must be at least 5 characters in length.
You can use the characters a...z, A...Z, 0...9 for the password.
Write the new password and press the change password.
A pop-up window appears: write the new password again
and press OK.
If the two new passwords are identical the password is
changed; if not, an error message appears and you have to
rewrite the password.
Press Home to return to the main menu, press <<-back to
return to the previous menu.