Usb; Ethernet; Rs232; Rs485 - gefran eView BOX Installation And Instruction Manual

Internal cabinet control panel
Hide thumbs Also See for eView BOX:
Table of Contents

Advertisement

USB

The USB ports let you connect external devices conforming
to the USB standard.
The connectors are Type A and the ports support the USB
2.0 standards, with speed up to 480 Mbit/s.
The ports can deliver 500 mA current at 5 VDC to power
external USB devices. The USB cable can have a maximum
length of 5 meters.
Use approved USB 2.0 cables.
Logging from panel into the controller's USB port is possible
through the carry-over cable (separately sortable). In order
to set the grip of this cable, the thickness of the panel in the
chosen position mustn't be higher than 2 mm.

Ethernet

The Ethernet port lets you connect the controller to a
computer or a corporate LAN or, if the product has the option,
to an ETHERCAT network.
Pin
Name
1
TX+
2
TX-
3
RX+
4
5
6
RX-
7
8
The connection cable to use, straight or crossover, depends
on the type of device that should be connected.
For example, to connect directly to a PC with a crossover
cable must be used.
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
Straight cable
Figure 19 - Straight and crossover Ethernet cables
For the connection, use a CAT6 UTP cable or superior, You
can also use a CAT5e cable (only for ETHERCAT).
The maximum length of the Ethernet cable is 100 metres.
Do not run the Ethernet cable alongside the machine power
cables, to avoid interference with data transmission.
The RJ45 socket has two LEDs. When the Ethernet connection
is active, the green LED stays permanently lit; when data is
being transmitted, the yellow LED flashes
20
Description
Data transmission +
Data transmission -
Data receiving +
Data receiving -
1
2
3
4
5
6
7
8
Crossover cable

RS232

The RS232 port is optional. Considering that the RS232 port
is not insulated, it is necessary to disconnect the power to
the Integrated Controller and internal cabinet control panel
and to the device to be connected before connecting them.
The connection cable must be screened and not exceed a
length of 3 metres. Tighten the cable connector to that of the
controller using the special screws.
1
Pin
Name
1
2
RxD
3
TxD
4
5
GND
6
7
RTS
8
CTS
9

RS485

The RS485 port is optional. Considering that the RS485 is
opto-isolated, it is not necessary to disconnect the power
to the internal cabinet control panel and to the device to
be connected before connecting them. Tighten the cable
connector to that of the controller using the special screws
1
Pin
Name
1
2
TX/RX+
3
1
2
4
TX/RX-
3
5
GND
4
6
5
6
7
7
8
8
9
Do not connect any filters other than the ones
described.
The RS485 connection can be used successfully over
long distances and in environments characterised by
considerable disturbance.
The maximum length of the cable depends on the
transmission speed, as shown in figure 22.
9
Description
Received Data
Transmitted Data
Ground
Request To Send
Clear To Send
9
Description
Data +
Data -
Ground
80949_MAN_eView BOX_05-2019_ENG
Signal
Input
Output
Ground
Output
Input