Operating And Error Indication; Fig. 7-2: Connector Panel Of The Box Build In The Vpp; Fig. 7-3: Leds At The Vpp 21 Box - Bosch Rexroth IndraControl VPP 21.1 Series Project Planning Manual

The operator terminals vpp 21 are pc-based machine operator terminals
Table of Contents

Advertisement

7-2
VPP 21 Box
7.2

Operating and Error Indication

Fig. 7-2:
Connector panel of the box build in the VPP 21
To indicate device states and errors 10 LEDs arranged at the connector
panel of the VPP 21 box are provided.
Start the measures specified in the following table, if one of the
succeeding LEDs indicates an error or a note.
LED
Designation
Display
1
VIN
LED green
LED OFF
2
VOUT
LED green
LED OFF
3
HD
LED yellow
4
BATT ERR
LED red
5
RDY_REL
LED green
6
TEMP
LED red
7
COM_RDY
LED yellow
8
COM_RUN
LED green
9
COM_ERR
LED red
10
COM_STA
LED yellow
Fig. 7-3:
LEDs at the VPP 21 box
Meaning
Measure
Normal mode
-
24 V DC missing
Verify supply voltage
Normal mode
-
Internal voltages
Verify supply voltage
missing
Hard disk access
-
Battery error.
Exchange battery
Voltage below limit
value.
READY contact
-
closed, no error
Temperature
-
prewarning
Ready of the COM
-
module
Run of the COM
-
module
Error of the COM
-
module
Status of the COM
-
module
DOK-SUPPL*-VPP*21.1***-PR02-EN-P
VPP 21.1
VPP21-BoxFront.jpg

Advertisement

Table of Contents
loading

Table of Contents