Maintenance

13 Error Causes and Elimination

Error
Enabling button not available
STOP function not available
Communication with network not available
Safety circuits cannot be closed
Tab. 13-1: Error causes and error elimination
14 Maintenance

14.1 General Information

NOTICE
If hardware or software components have to be exchanged, please contact the
Bosch Rexroth Service or ensure that only skilled staff changes the respective
components.
NOTICE
Do not use any solvents (e. g. diluents)!
Do not use compressed air, steam jet and high pressure cleaning devices!

14.2 Regular Maintenance Tasks

At least once a year, all plug and terminal connections of the components are
to be checked regarding proper tightness and possible damage
18/27
Measures for error elimination
Enabling button defective, replace device
STOP button defective, replace device
Check entries in Rexroth settings
Screw on connection plug completely. If the
contacts are bent, replace the connection ca-
ble
Check the cable and replace if required
Network topology
Completely insert the connector
If the contacts are bent or in case of a cable
break, replace the connection cable
If a safety component is defective, replace the
device
Maintenance work in the device is only permis-
sible by skilled staff!
Dissolution of the foil surface as well as the
seal by solvents or by high pressure cleaning
devices!
VCH 05.1
DOK-SUPPL*-VCH*05*****-IT02-EN-P