Ambient Conditions; Fig. 4-3: Technical Data: Pc; Fig. 4-4: Ambient Conditions - Bosch Rexroth IndraControl VPP 21.1 Series Project Planning Manual

The operator terminals vpp 21 are pc-based machine operator terminals
Table of Contents

Advertisement

4-2
Technical Data
4.3
PC
Processor
Main memory
Interfaces
Additional interface via a
COM module
Slots for connector panel
Slot
4.4

Ambient Conditions

Ambient temperature
(surrounding air temperature)
Max. temperature gradient
Relative humidity
Air pressure
Mechanical strength
Pentium III with minimum 700 MHz and integrated graphic controller
with maximum 4 Mbytes video memory
1 x external VGA connection (15-pin, HD-Sub)
2 x Ethernet connection (RJ 45, 10/100 Base-T)
1 x USB interface
1 x serial standard interface
1 x keyboard connection (PS/2)
1 x mouse connection (PS/2)
2 x 24 V outputs
Profibus DP Master/Slave
1 x slot for Compact Flash Card
1 x slot for 2.5" hard disk
1 x PCI slot for short cards
Fig. 4-3:
Technical data: PC
Operation
+5 ... +45 °C with housing fan
+5 ... +25 °C without housing fan
Temporal temperature changes up to 3 °C
per minute
Climatic class 3K3 according to
EN 60721, non-condensing.
Max. 80 % humidity for 25 °C
Up to 2,000 m above MSL according to
DIN 60204
Max. vibration:
Frequency range:
10 ... 150 Hz
Excursion:
0.075 mm
at 10 ... 57 Hz
Acceleration:
1 g at 57 ... 57 Hz
Test duration for
10 frequency cycles
each axis:
Frequency
sweep rate:
1 octaver/min
According to EN 60068-2-6, test Fc
Fig. 4-4:
Ambient conditions
512 MB SO-DIMM DRAM
Storage/transport
-20 °C to +60 °C
Temporal temperature changes up to 3 °C
per minute
Climatic class 3K3 according to
EN 60721, non-condensing.
Max. 80 % humidity for 25 °C
Up to 3,000 m above MSL according to
DIN 60204
Max. shock:
15 g according to EN 60 068-2-27, no
malfunction
DOK-SUPPL*-VPP*21.1***-PR02-EN-P
VPP 21.1

Advertisement

Table of Contents
loading