DOK-SUPPL*-VEP*XX.4***-PR03-EN-P
Rexroth IndraControl VEP **.4 Embedded Terminal
6
Display and Operating Components
6.1
Operating and Error Display
Displays on the front
In the upper part of the front panel, there are four LEDs to indicate the device
states and the errors of the connected PC. Depending on the variant the front
panel provides either labeled LEDs or illuminated symbols. The meaning of the
display elements and measures in the event of failures are listed in the following
table (see
fig. 6-1 "LEDs for operating and error display on the front panel" on
page
77).
Symbol or LED Display
LED green on
LED green off
HDD
LED yellow
Temp
LED off
LED flashes red Temperature > 50 °C
UPS
LED off
LED red
LED flashes red Battery pack is dis‐
Fig.6-1:
LEDs for operating and error display on the front panel
Bosch Rexroth AG
Display and Operating Components
Meaning
Measure
Normal mode
–
No DC 24 V supply volt‐
Check the supply volt‐
age
age at the power supply
unit!
Hard disk access
–
Temperature in safe
–
range
Reduce surrounding air
temperature!
Fan might possibly be
connected!
Normal mode
–
Device is currently oper‐
Restore supply voltage,
ating in battery mode,
initiate controlled restart
i. e. no power supply is
of the control cabinet
available!
PC!
Check battery!
charged, is defective or
is not connected.
77/139