Network Settings - FOR-A MFR Series Operation Manual

Web-based control
Table of Contents

Advertisement

3.
Specify the salvo number (in the range from 1 to 100).
Input a salvo name if necessary. The salvo name can be freely specified, and the
specified name is displayed on the remote control panel salvo button.
4.
Select the crosspoints to save as a salvo. The MFR-5000/8000/3000 allows you to save
up to 15,000 crosspoints and MFR-1000/1616/1616R/3216/3232/1616A up to 5,120
crosspoints.
Up to 256 crosspoints can be saved to a single salvo in MFR-1000/ 1616/ 1616R/ 3216/
3232/1616A/3000 and 512 in MFR-5000/8000.
5.
Select the destination channels to save. The selected channels are highlighted yellow.
6.
Click the Entry button to register salvos.
Deleting a crosspoint
▼By selecting a destination channel
1.
Click a destination channel to delete. The clicked channel turns gray.
2.
Click the Entry button. Only yellow-highlighted destination channels are registered.
▼By using the Delete button
1.
Click the Stop Set button.
2.
Click the Delete button.
3.
The Delete button and crosspoints are highlighted yellow. Click a crosspoint from among
those highlighted. Click the Delete button to exit Delete mode.
4.
Click the Setting button.
5.
Click destination channels to highlight them yellow.
6.
Click the Entry button.

4-1-7. Network Settings

The Network Settings page allows you to set network settings.
Factory Default Settings
Default user name and password settings for logging into an MFR Main Unit are as shown
below:
User name:
user (factory default setting)
Password:
password (factory default setting)