Console Redirection Submenu - Seco SBC Series User Manual

With the n-series intel pentium/celeron and x5-series atom socs in the embedded nuc form factor
Hide thumbs Also See for SBC Series:
Table of Contents

Advertisement

4.3.7 Console Redirection submenu

Menu Item
Options
Console Serial Redirect
Enabled / Disabled
VT_100 / VT_100+ /
Terminal Type
VT_UTF8 / PC_ANSI
115200 / 57600 / 38400 /
Baud rate
19200 / 9600 / 4800 / 2400
/ 1200
Data Bits
7 bits / 8 bits
Parity
None / Even / Odd
Stop Bits
1 bit / 2 bits
None
Flow Control
RTS/CTS
XON/XOFF
0 Seconds / 2 Seconds / 5
Information Wait Time
Seconds / 10 Seconds / 30
Seconds
C.R. After Post
Yes / No
AutoRefresh
Enabled / Disabled
FailSafeBaudRate
Enabled / Disabled
ACPI SPCR Table
Enabled / Disabled
PCI_HS_UART 0:30:3
See submenus
PCI_HS_UART 0:30:4
SBC-A80-eNUC
SBC-A80-eNUC User Manual - Rev. First Edition: 1.0 - Last Edition: 1.2 - Author: S.B. - Reviewed by G.G Copyright © 2017 SECO S.r.l.
Description
Enable or disable Console redirection. When enabled, all the submenus of the following paragraph will appear
Set Console Redirection terminal type
Set Console Redirection baud rate
Set Console Redirection data bits
Set Console Redirection parity bits
Set Console Redirection stop bits
Set Console Redirection flow control type
Set Console Redirection port information display time
Console Redirection continues to work even after Bios POST.
When this feature is enabled, the screen will auto refresh once after detecting the connection of a remote
terminal
This feature will auto detect remote terminal baud rate and connect C.R serial device with detected baud rate
Serial Port Console Redirection Table.
When this feature is enabled, the SPCR table will be add-into ACPI tables.
See submenus
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sbc-a80-enuc

Table of Contents