Edp Connector - Seco SBC Series User Manual

With the n-series intel pentium/celeron and x5-series atom socs in the embedded nuc form factor
Hide thumbs Also See for SBC Series:
Table of Contents

Advertisement

3.3.5

eDP Connector

eDP connector - CN9
Pin nr.
Pin name
1
N.C.
2
SW_BACK
3
SW_BACK
4
SW_BACK
5
SW_BACK
6
N.C.
7
N.C.
8
eDP_BLT_CTRL
9
eDP_BACKLIGHT_EN
10
GND
11
GND
12
GND
13
GND
14
eDP_HPD
15
GND
16
GND
17
N.C.
18
SW_VDD
19
SW_VDD
20
GND
21
eDP_AUX-
22
eDP_AUX+
23
GND
24
eDP_TX0+
25
eDP_TX0-
26
GND
27
eDP_TX1+
28
eDP_TX1-
29
GND
30
N.C.
SBC-A80-eNUC
SBC-A80-eNUC User Manual - Rev. First Edition: 1.0 - Last Edition: 1.2 - Author: S.B. - Reviewed by G.G Copyright © 2017 SECO S.r.l.
On the SBC-A80-eNUC board, the Digital Display Interface #1 is reserved for the connection of LCD panels having an
embedded Display Port interface.
For the connection of this kind of displays, on-board there is a VESA
for Display Port interface, type I-PEX p/n 20455-030E-02.
Mating connector: I-PEX p/n 20454-030T.
On this connector, SW_BACK and SW_VDD are the voltage rails that can be used to supply the LCD and related
Backlight Unit.
The LCD software-driven voltage, i.e. signal SW_VDD, can be
regulated to be connected to +3.3V_A or +5V_A by closing (short-
circuiting) breakers BR3 or BR4, respectively (only one breaker at a
time, otherwise there will be a short circuit between the two different
voltages).
Similarly,
the
backlight
software-driven
SW_BACK, can also be regulated to be connected to +5V_A or
+12V_A by closing (short-circuiting) breakers BR1 or BR2, respectively (only one breaker at
a time, otherwise there will be a short circuit between the two different voltages).
Please refer to the figure on the left for an indication of the placement on the PCB of the four
breakers mentioned above (they are located on the bottom side, near connector CN27).
Please take care of closing only one breaker per voltage rail (i.e., BR1 or BR2, BR3 or BR4),
otherwise there will be short circuits between the main power rails of the board.
Upon specific request, the board can be supplied configured with the desired voltages
already set. Please contact your Sales Representative for details about this.
®
certified connectors
Breaker closed SW_VDD Voltage
BR4
BR3
Breaker closed SW_BACK Voltage
BR2
voltage,
i.e.
signal
BR1
+5V_A
+3.3V_A
+12V_A
+5V_A
28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sbc-a80-enuc

Table of Contents