XSCF> addfru
b. Install the CMU according to the instructions displayed in the maintenance
menu.
Refer to Section 6.2, "Active Replacement and Hot Replacement," in the SPARC
Enterprise M8000/M9000 Servers Service Manual.
Note – Be sure to perform diagnosis of the newly mounted CMU in the
Maintenance menu of the addfru(8) command.
10. Use the showhardconf(8) command to confirm that the installed CPU module
is recognized by the server and that the error indicator asterisk (*) is not
displayed.
XSCF> showhardconf -M
11. Use the showlogs(8) and showstatus(8) commands to confirm that no
abnormality has occurred.
XSCF> showlogs error -v
XSCF> showstatus
12. Change the key position on the operator panel from Service to Locked.
13. Set the following for the CMU:
Set up XSB.
■
Set up the domain.
■
Set up the CPU operational mode on the domain.
■
Refer to Chapter 2, "Setting Up XSCF," in the the SPARC Enterprise
M4000/M5000/M8000/M9000 Servers XSCF User's Guide for information about
these settings.
14. Use the setdomainmode(8) command to disable the autoboot function of the
domain.
Refer to the SPARC Enterprise M4000/M5000/M8000/M9000 Servers XSCF User's
Guide and the setdomainmode(8) man page for more information.
15. Power on the domains.
XSCF> poweron -d domain_id
Sun SPARC Enterprise M8000/M9000 Servers Product Notes
29