Sun Microsystems SPARC Enterprise M8000 Product Notes page 48

Hide thumbs Also See for SPARC Enterprise M8000:
Table of Contents

Advertisement

Note – Be sure to perform diagnosis of the newly mounted CMU in the
Maintenance menu of the addfru(8) command.
3. Use the showhardconf(8) command to confirm that the installed CPU module
is recognized by the server and that the error indicator asterisk (*) is not
displayed.
XSCF> showhardconf -M
4. Use the showlogs(8) and showstatus(8) commands to confirm that no
abnormality has occurred.
XSCF> showlogs error -v
XSCF> showstatus
5. Change the key position on the operator panel from Service to Locked.
6. Set the following for the CMU:
Refer to Chapter 2, "Setting Up XSCF," in the the SPARC Enterprise
M4000/M5000/M8000/M9000 Servers XSCF User's Guide for information about
these settings.
7. Power on the domains.
XSCF> poweron -d domain_id
8. Confirm that the target domain has been correctly started.
XSCF> showlogs power
9. Use the showlogs(8)and showstatus(8) commands to confirm that no
abnormality has occurred.
XSCF> showlogs error -v
XSCF> showstatus
34
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1071 • July 2008
Set up XSB.
Set up the domain.
Set up the CPU operational mode on the domain.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPARC Enterprise M8000 and is the answer not in the manual?

This manual is also suitable for:

Sparc enterprise m9000

Table of Contents