Additional Software Procedures; Booting From A Wan Boot Server - Sun Microsystems SPARC Enterprise M8000 Product Notes

Hide thumbs Also See for SPARC Enterprise M8000:
Table of Contents

Advertisement

Software Documentation Updates (3 of 3)
TABLE 9
Document
Sun SPARC Enterprise
M4000/M5000/M8000/M9000
Servers Administration Guide
Sun SPARC Enterprise
M4000/M5000/M8000/M9000
Servers XSCF Reference Manual
Sun SPARC Enterprise
M4000/M5000/M8000/M9000
Servers XSCF Reference Manual
Sun SPARC Enterprise
M4000/M5000/M8000/M9000
Servers XSCF Reference Manual

Additional Software Procedures

This section contains instructions for accomplishing some of the workarounds
mentioned earlier in this document.

Booting From a WAN Boot Server

The WAN boot installation method enables you to boot and install software over a
wide area network (WAN) by using HTTP. To support booting the Sun SPARC
Enterprise M8000/M9000 server from a WAN boot server, you must have the
appropriate wanboot executable installed to provide the needed hardware support.
If you have added SPARC64 VII processors to your server, for example, you must
perform this procedure even if you have performed it previously, before the new
processors were added.
For information about WAN boot servers, refer to the Solaris 10 Installation Guide:
Network-Based Installations for the version of Solaris 10 OS that you are using. You
can find Solaris 10 OS documentation here:
22
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1071 • July 2008
Page Number
Change
Page 70
"About Auditing" section. Add the following note at the
end of the "Audit File Tools" section:
Note - This chapter describes how to set up archived log
files. The SP Security (SUNWspec) Package gives
administrators and service providers a means to view
those files. To display the XSCF audit log files archived to
your server, use the viewauditapp(8) and
mergeaudit(8) off-platform audit file viewers.
The maximum length of the user name is 31 characters.
adduser(8)
man page
The adduser(8) man page erroneously documents a
maximum user name length of 32 characters.
The sendbreak(8) command will not work when the
sendbreak(8)
man page
domain mode is set to on while the mode switch on the
operator panel is set to locked. Refer to the
setdomainmode(8) man page for more information.
The viewaudit(8) man pages show incorrect output for
viewaudit(8)
man page
Example 5 and Example 6.