▼ To Add a New SPARC64 VII-Equipped CMU as
a New Domain
Note – If you want to install Solaris 10 8/07 on the new domain, you must install
from a patched image on the installation server. (See
1. Log in to the XSCF using an account with platadm privileges.
2. Use the showstatus(8) command to confirm that no FRU is currently listed in
Faulted or Deconfigured status.
XSCF> showstatus
No failures found in System Initialization.
3. Change the key position on the operator panel from Locked to Service.
4. Collect an XSCF snapshot to archive system status prior to upgrade.
If a problem should occur during the upgrade procedure, a snapshot of the
system status might be helpful.
XSCF> snapshot -t user@host:directory
5. Update the XCP version to 1071.
Before updating firmware to XCP 1071, refer to
page
M4000/M5000/M8000/M9000 Servers XSCF User's Guide.
6. Reset the XSCF firmware.
XSCF> rebootxscf
7. Log in to the XSCF again, using an account with fieldeng privileges.
8. Install the CPU module (CPUM) on the CMU to be added.
For instructions, refer to Section6.4.1, "Replacing a CPU module," in the SPARC
Enterprise M8000/M9000 Servers Service Manual.
9. Install the CMU from
a. Execute the addfru(8) command and select CMU/IOU from the Maintenance
28
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1071 • July 2008
5. For instructions for updating the firmware, refer to the SPARC Enterprise
Step 8
menu.
Step
"Upgrading to XCP 1071" on
on the server.
18.)