XSB#01-2 : 02.02.0000 (Reserve), 02.03.0000 (Current)
XSB#01-3 : 02.02.0000 (Reserve), 02.03.0000 (Current)
...
13. Turn off the power to the target domain.
XSCF> poweroff -d domain_id
14. Continue with the appropriate installation procedure:
a. If you are adding an entire new SPARC64 VII–equipped CMU to a domain
configured with SPARC64 VI processors, continue with
SPARC64 VII-Equipped CMU to a Domain Configured With SPARC64 VI" on
page
33.
b. If you are upgrading an existing CMU in an existing domain to SPARC64
VII processors, continue with
on an Existing Domain" on page
▼ To Add a New SPARC64 VII-Equipped CMU to a
Domain Configured With SPARC64 VI
Use this procedure if you are adding a new CMU containing SPARC64 VII
processors to an existing domain that is already configured with SPARC64
processors.
1. Install the CPU module (CPUM) on the CMU to be added.
For instructions, refer to Section6.4.1, "Replacing a CPU module," in the SPARC
Enterprise M8000/M9000 Servers Service Manual.
2. Install the CMU from
a. Execute the addfru(8) command and select CMU/IOU from the Maintenance
menu.
XSCF> addfru
b. Install the CMU according to the instructions displayed in the maintenance
menu.
Refer to Section 6.2, "Active Replacement and Hot Replacement," in the SPARC
Enterprise M8000/M9000 Servers Service Manual.
"To Upgrade an Existing CMU to SPARC64 VII
35.
Step 8
on the server.
Sun SPARC Enterprise M8000/M9000 Servers Product Notes
"To Add a New
33