5.17 Options Up/Downloading?

NOTE: THE FUNCTIONS LISTED BELOW APPLY ONLY TO PSTN (DIGI-1200) – SEE SECTION
7 FOR OTHER CONNECTION METHODS
The Uploading/Downloading PC Software allows the servicing and monitor of the system and review of
the logs.
Dial Mode Option
This function programs the procedure used for the call between PC and panel:
Auto Answer: When called from a PC the panel will answer the call immediately.
Dial Back: When called from PC the panel will take the line, disconnect and call the PC.
Panel Dials: Does not allow the PC to dial into the panel. A call has to be initiated by the user or
engineer from the panel.
Dial In Options
Direct Dial: When the PC dials the panel, it will respond immediately.
AMC Dial (Shared Line): When the PC dials the panel, it will hang up after a designated number of
rings, and dial again. The first call primes the panel, which will then answer the second call. The
number of rings to prime the panel is entered in "Number of Rings before AMC" menu option.
Number of Rings before AMC: Enter the number of rings needed to prime the panel before answering
the next call.
Prefix Telephone Number: The prefix is an extra digit required to reach the panel i.e. dial 9 to get an
'outside' line. This is the phone number of the PC modem where the UDL is installed for performing
the automatic remote maintenance service. Press a button to add any symbols: ',' = 2 second
pause, '+' for roaming calls.
Redials: The number of redials that it will call to the InSite software before it fails.
UDL Password: This password is used to identify the UDL connection. Make sure the password here
and on the PC InSite software are the same.
Site Name: If a Site Name is entered, it must be also entered on the UDL software otherwise the
connection will fail.

5.18 PC Connect Menu?

NOTE: THE FUNCTIONS LISTED BELOW APPLY ONLY TO PSTN (DIGI-1200)
The PC Connect Menu can be used by the engineer to make the panel dial to a remote PC where the
UDL software is installed (rather than the PC dialling the control panel). This menu is also available
from the Master Manager menu to enable them to activate a connection from user mode.
5.18.1 Select PC to Dial
Select PC 1 to 4. The telephone number of the PC modem/s (1 to 4) should be pre-programmed in
'Options Up / Downloading' menu.
Select PC to Dial  Select Operation
If the customer has not been created in UDL software it will take the data automatically from panel
and create customer. If the customer has been created in the UDL the panel will connect to this
customer database.
Test Call  Send test call to the ARC.
RM Service – Will force RM Service report for the last 6 months.
Data from PC, Data to PC – Up/Down loading info from/to UDL.
Diagnostics – Forces full panel diagnostic test and sends it to UDL setting new service date.
Commissioning – Just sets a date when the system is going to be used from.
NOTE: There is a shortcut to connect to 'PC number 1' from when the panel is in disarmed mode.
To activate such a call from the keypad, press a followed by 5555. The display will not change
but Enforcer 32-WE will dial the first PC programmed in 'Options Up / Downloading' automatically.