Pyronix Enforcer 32-WE Programming Reference Manual page 27

Wireless alarm system
Hide thumbs Also See for Enforcer 32-WE:
Table of Contents

Advertisement

Auto Set Up?
Yes: The Enforcer will obtain the set up data from the router using DHCP.
No: The following will be required:
IP Address: Enter the IP Address where xxx is a number between 1 & 255.
o
Subnet Mask: For most domestic installations the subnet mask will be 255.255.255.0.
o
Gateway: Enter the gateway, which is the routing device that the Enforcer is connected
o
to.
1
st
DNS IP Address: Enter the DNS Server IP Address.
o
2
nd
DNS IP Address: Enter the alternative DNS server IP address if required.
o
Program Wi-Fi
For future use.
5.15.3 ARC signalling
The Enforcer 32-WE system can communicate with an Alarm Receiving Centre (ARC) using the LAN
module or the GPRS modem.
ARC Details: Choose which ARC to program from 1 to 4.
Formats Available:
Contact ID IP = See page: 41 for the event table.
SIA IP = See page: 41 for the event table.
Valid Areas:
This option permits the set up a different ARC for a different area. Select which area this particular
ARC will be reporting. Selecting ABCD means the ARC will be receiving events from all areas.
Area ARC Account  One Area Account
This options permits the engineer to set up individual area account for each area or open common
account for all of them. Use the a key to add hexadecimal values; B to F. Numbers are entered
by the number keys.
Redials: If the alarm event has not been received by the monitoring station after the first number
has been called the second number will be called. The 2 numbers will be alternated as many times
as the redials are set to. If a call has been acknowledged by the monitoring station then the panel
will stop calling.
Timeout: This is the time of how long it takes a call to timeout before it is not answered.
Test Calls:
The test call is used to show that the system is still alive when no activations have been made.
Setting up a test call asks for start time in hours and minutes and the frequency of call in days,
hours & minutes.
Event Types: Please see page: 41 for all event options. If 'Custom' is selected, all event types can
be chosen.
Sign Up ARC:
ARC Sign UP IP: The ENIP Address that is supplied by the ARC.
ARC Sign Up Port: The Port of the ENIP Server that is supplied by the ARC.
Security:
Standard: Requires a password and connection handle (supplied by the ARC),
High: Send Key by SMS:
Yes: The security key will be sent by the ARC software to the Enforcer.
o
No: The security key and connection handle must be entered manually.
o
Send Sign Up to ARC?
Sign Up Successful: A message will be displayed indicating that the sign up was
o
successful.
Sign Up Failed: This may be due to the following reasons:
o
Incorrect Security Key
Incorrect Connection Handle
ARC Server not available
Account already exists