5.19 Software Revision?

This option shows the software version and hub version installed in the panel. Please obtain the
software version number prior to contacting customer support so that the correct information can be
given upon supporting the product.

5.20 Factory Default?

This option is used to reset the panel to a factory default.
5.20.1 Factory Default Code
Currently the system has 2 default settings. One is EN50131 default and the other default is not
compliant to EN50131. The non EN default code is 2000 and the EN default code is 2002.
NOTE: Notice that the panel comes as defaulted to non EN50131 system and if used under the EN
50131 installation requirements MUST be defaulted to EN50131 by using the default code of
2002.Once applied the factory default code the system will be reset to factory defaults.
5.20.2 Clear WLs Data?
This option will give the installer the option not to clear wireless devices if they have been
programmed on the system already.
5.20.3 Clear Codes?
This option will give the installer the option not to clear user codes if they have been programmed
on the system already.
5.20.4 Clear Logs?
This option will give the installer the option not to clear memory logs if they have been
programmed on the system already.

5.21 Exit Engineer Menu?

There are 2 ways to exit from engineer menu. One way is from this option and the other quick way
is by pressing a from any other main menu.

6. Adding External Wired Keypad

The keypads have a small internal menu used mostly for addressing, changing key click volume and
brightness of the LCD display.
Entering and Exiting the Keypad Menu
To enter the keypad menu, press and hold the d button until 'SECURITY CODE:' is displayed, and then
enter '2000'. To exit, press the a key.
Keypad Menu Options
ADDRESS = Used to assign an address to a keypad [00] is the keypad on the panel
LANGUAGE = Allows you to assign a language –used for the keypad menu only
KEYPAD INPUTS READING = Shows the resistor reading / status on the 2 inputs located on the keypad
KEY-CLICK VOLUME = Sets the volume of the buttons
TAG VOLUME = Sets the volume when tag used
KEYPAD VOLUME = Sets the general volume of the keypad
ID TAG = Used to read the unique ID number of the Tag
RESET KEYPAD = Resets the keypad to factory settings
BACKLIGHT = Sets the backlight intensity of the keypad
DELAY FIRE AND PA BUTTONS = Sets how long the PA and Fire buttons have to be pressed for before
an alarm is created
Testing The Keypad
With the system disarmed, press and hold the b key for 10 seconds at any keypad. This will cause
all the LEDs on that keypad to illuminate and the LCD screen to scroll a display testing each pixel. The
keypad will revert to normal display approximately 10 seconds after the b key is released.