Engineer Restore Options; Communications - Pyronix Enforcer 32-WE Programming Reference Manual

Wireless alarm system
Hide thumbs Also See for Enforcer 32-WE:
Table of Contents

Advertisement

5.14 Engineer Restore Options?

Restore Burglary
Restore PA
Restore Tamper
Restore Soak
Restore Faults
Anti-code Restore

5.15 Communications?

The 'Communications' function programs the App, network, ARC, SMS and UDL facilities.
5.15.1 App Set Up
The Pyronix+ App is available in 2 versions: Android from Google Play Store; and iOS from the
Apple store. Please refer to the User Manual for set up details.
Enable App: Enables the app functionality.
System ID: Displays the unique Enforcer serial number required to register the Enforcer with the
Pyronix Cloud.
Cloud Password: A password is required to allow remote access.
Security
Standard: Requires only a password for connection.
High: 3 security options are required:
Generate App Password Key: A 24 character Hex-key is generated.
o
View App Password Key: Displays the key that has previously been generated.
o
Send Password Key in an SMS (when a GPRS module is fitted): Once a mobile
o
number is entered, an SMS is sent with the security key.
Poll Server
Yes: The Enforcer will poll with the App server regularly. The polling will be done often
enough so that the Pyronix Cloud is aware of the Enforcer's location.
No: The Enforcer will not poll with the App server. An SMS being sent to the Enforcer may
be required to initiate communication.
The timing of the poll will be adjustable from the Pyronix Cloud. This will be allocated as an option
for each panel. It will be adjustable from 1 – 99 seconds (default 8 seconds).
NOTE: If more than 8 seconds is selected a warning will be given that this will use more data and
incur higher call costs.
5.15.2 Network Set Up
Three different modules can be connected to the Enforcer to enable different forms of
communication. Please refer to the Installation Reference manual for information. The sub-menus
will be enabled only for the module installed.
Program GPRS?
GPRS APN: Enter the GPRS APN, for example 'orange internet'.
GPRS User ID: Enter the GPRS user ID if the network requires this.
GPRS Password: Enter the GPRS password if the network requires this.
Program LAN?
If 'Yes', then the user code will silence the alarm but the engineer must reset the
system with the engineer code before it can be used again. This will not interfere with
the generation of PA alarm.
If 'Yes', the Engineer can only reset the Enforcer 32-WE after any PA alarms.
This will not interfere with the generation of Gas and Fire alarm.
If 'Yes', the Engineer can only reset the Enforcer 32-WE after any tamper alarms.
If 'Yes', the Engineer can only reset the Enforcer 32-WE after any activated inputs that
are under soak test.
If 'Yes', the Engineer can only reset the Enforcer 32-WE after any of the below faults:
ATE telecom fail, Modem fail, ATE single path fail, Telecom line fail, Battery disconnect,
Battery charge, Battery load, Excessive charge, Battery critical, Device fail. Mains faults
are excluded.
If 'Yes', then the system displays (if one of the above features is enabled) an anti-code
number. This code is used by the engineer to generate a reset code via a special
software kit, the reset code is then given to the user to reset the system.
Page: 26

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents