6. Install the Sbus card as follows (
7. Install the screws and washers into the SBus card back plate (
a. Slide the card at an angle into the back panel of the system. Hook the card back
plate under the lip on the back panel. Be sure the SBus card back plate shows
through the slots on the back panel.
Note – The back plate connector(s) may not align with other connectors in the back
panel.
Caution – Do not use force. Align the card connector and slot properly or card pin
damage may occur.
b. Align the SBus card connector with the SBus slot on the system board. Gently
press the corners of the card to seat the connector into the slot.
c. Push the retainers forward over the edge of the SBus card.
8. Remove the wrist strap and replace the cover.
See Chapter 7.
9. Power on the system.
See Chapter 6.
FIGURE 11-19
158
SPARCstation 20 Service Manual • July 1996
Washer (2)
Screw (2)
SBus Card Back Panel Screws and Washers
):
FIGURE 11-18
).
FIGURE 11-19