Adjusting of the minimum of the top burners
In the minimum position the flame must have a length of about 4 mm and
must remain lit even with a quick turn from the maximum position to that
of minimum.
The flame adjustment is done in the following way:
* Turn on the burner
* Turn the tap to the MINIMUM position
* Take off the knob
* With a thin screwdriver turn the screw
* F until adjustment is correct (fig. 2.12).
Normally for LPG, the regulation screw is tightened up.
Auxiliary,
Semi-rapid and
Rapid burners
Fig. 2.10
F1
Fig. 2.12