  EV Charger-related Troubleshooting

EV Charger-related Troubleshooting

For the following system errors, when an error occurs, the red LED lights ON and the
buzzer beeps 10 times.
The error message is displayed on the SolarEdge mobile app screen.
If the error persists- contact SolarEdge Support.
Error code
3x85
EVSE Comm. Error
Over Current
1Cx1; 1Cx8
Press Charge Now
Over Voltage
1Cx2; 1xC9
Press Charge Now
1Cx3,Cx14;
Ground Fault (RCD)
1Cx15
Press Charge Now
Displayed Error message
EV Charging Single Phase Inverter MAN-01-00629-1.2
Description and Troubleshooting
An internal communication error.
When this error occurs, the red
LED is not lit, the buzzer does not
beep and charging is not affected.
Check that the internal connections
on the communication board are
properly done.
EV Charger AC over current.
Press the Charge Now
pushbutton on the Connection
Unit with Safety Switch, see
Figure 5 .
-or-
Tap Charge Now on the EV
Charger tab of the Monitoring
App
EV Charger AC voltage too high.
Press the Charge Now
pushbutton on the Connection
Unit with Safety Switch, see
Figure 5 .
-or-
Tap Charge Now on the EV
Charger tab of the Monitoring
App
EV Charger ground fault detected.
Press the Charge Now