Technical Specifications - EV Charging Single Phase Inverter - (Australia)
ADDITIONAL FEATURES
Supported Communication
Interfaces
Smart Energy Management
Inverter Commissioning
STANDARD COMPLIANCE
Safety
Grid Connection Standards 
Emissions
INSTALLATION SPECIFICATIONS
AC Output Conduit Size / Wire cross
section
DC Input Conduit Size / # of Strings
/ Wire cross section
Dimensions with Connection Unit
with Safety Switch (HxWxD)
Weight with Connection Unit with
Safety Switch
Noise
Cooling
Operating Temperature Range
Protection Rating
(1)
For more information refer to
control-zigbee-module-datasheet.pdf
(2)
Wi-Fi connectivity requires an external antenna. For more information refer to:
https://www.solaredge.com/sites/default/files/se-wifi-zigbee-antenna-datasheet.pdf
(3)
Import/Export meter is required for Export Limitation and for controlled Excess Solar charging
(4)
Full power up to at least 50°C/122°F . For power de-rating information refer to:
https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf
EV Charging Single Phase Inverter MAN-01-00629-1.2
RS485, Ethernet, ZigBee for Smart Energy
(1)
(optional), Wi-Fi (requires antenna)
Export Limitation and Excess Solar
with the SetApp mobile application using
built-in Wi-Fi access point for local
connection, Cellular (optional)
IEC62109, AS/NZS3100
IEC61000-6-2, IEC61000-6-3, IEC61000-3-
11, IEC61000-3-12, FCC Part 15 Class B
25mm Maximum / 1-13 mm
25mm Maximum / 1-2 srings / 1-13 mm
IP65 — Outdoor and Indoor
:
https://www.solaredge.com/sites/default/files/se-device-
(optional)
(3)
Charging
AS/NZS4777:2015
450 x 370 x 174
11.4
<25
Natural Convection
(4)
-40 to +60
    84
(2)
 
 
 
 
 
 
2
 
2
 
mm
kg
dBA
 
°F/ °C
 