7-INSTALLATION (continued)
WARNING
• To reduce the risk associated with sharp
blade hazards:
− Keep hands and fi ngers away from tape
cutoff blades under orange blade guards.
The blades are extremely sharp.

7.8 Preliminary Electric Inspection

Before connecting the machine to the mains please
carry out the following operations:
7.8.1 Make sure that the socket is provided with an
earth protection circuit and that both the mains
voltage and the frequency match the specifi -
cations on the name plate.
7.8.2 Check that the connection of the machine
to the mains meets the safety regulations in
your country.
WARNING
To reduce the risk associated with
mechanical and electrical hazards:
Read, understand, and follow all safety
and operating instructions before operating
or servicing the case sealer.
To reduce the risk associated with
hazardous voltage:
Position electrical cord away from foot
and vehicle traffi c.
7.8.3 The machine is fi tted with a main switch.
The user will be responsible for testing the
short-circuit current in its facility and should
check that the short-circuit amperage setting
of the machine is compatible with all the
components of the mains system.
a80b-NA
7.9
Machine Connection to the Mains
- Push the LATCHING EMERGENCY STOP
BUTTON.
- The main switch is normally turned OFF.
Connect the power cord supplied with the machine
to a wall socket using a plug which complies with the
safety regulations of your country.

7.10 Inspection of Phases

(For Three-Main Phases Only)
N/A for this machine.