Upkeep and maintenance

6.1

Firmware update - via WBM

Requirement
● The device has an IP address.
● The "admin" user is logged on.
Firmware update via HTTP
1. Click "System > Load&Save" in the navigation area. Click the "HTTP" tab.
2. Click the "Load" button in the "Firmware" table row.
3. Go to the storage location of the firmware file.
4. Click the "Open" button in the dialog. The file is uploaded.
Firmware update - via TFTP
1. Click "System > Load&Save" in the navigation area. Click the "TFTP" tab.
2. Enter the IP address of the TFTP server in the "TFTP Server IP Address" input box.
3. Enter the port of the TFTP server in the "TFTP Server Port" input box
4. Click the "Load file" button in the "Firmware" table row.
5. Go to the storage location of the firmware file.
6. Click the "Open" button in the dialog. The file is uploaded.
Result
The firmware is has been transferred completely to the device and under ""Information >
Versions" there is also the entry "FirmwareRunning". FirmwareRunningshows the version of
the current firmware. Firmware shows the firmware version stored after loading the firmware.
To activate this firmware, restart the device with "System > Restart".
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08