Configuring with Web Based Management
5.5 "System" menu
● "SNMPv1 Traps" check box
Enable or disable the sending of traps (alarm frames). You can configure other settings in
"System > SNMP > Traps".
● "DHCP Client" check box
Enable or disable the DHCP client. You can configure other settings in "System > DHCP
Client".
● "SINEMA Configuration Interface" check box
If the SINEMA configuration interface is enabled, you can download configurations to the
device via the TIA Portal.
● "Configuration Mode" drop-down list:
Select the mode from the drop-down list. The following modes are possible:
– Automatic Save
– Trial
Procedure
1. To use the required function, select the corresponding check box.
2. Select the options you require from the drop-down lists.
3. Click the "Set Values" button.
140
Automatic save mode. Approximately 1 minute after the last parameter change or
when you restart the device, the configuration is automatically saved.
Trial mode. In Trial mode, although changes are adopted, they are not saved in the
configuration file (startup configuration).
To save changes in the configuration file, use the "Write Startup Config" button. The
"Write Startup Config" button is displayed when you set trial mode. The message
"Trial Mode Active – Press "Write Startup Config" button to make your settings
persistent." is also displayed in the display area as soon as there are unsaved
changes. This message can be seen on every WBM page until the changes made
have either been saved or the device has been restarted.
SCALANCE W780/W740 to IEEE 802.11n Web Based Management