Configuring with Web Based Management
5.7 "Layer 2" menu
● P.t.P. Type
Select the required option from the drop-down list. The selection depends on the port that
is set.
– P.t.P.
– Shared Media
– "-"
● P.t.P.
– Enabled
– Disabled
● Hello Time
Enter the interval after which the bridge sends configuration BPDUs. As default, 2
seconds is set.
Range of values: 1-2 seconds
Note
The port-specific setting of the Hello time is only possible in MSTP compatible mode.
Procedure
1. In the input cells of the table row, enter the values of the port you are configuring.
2. From the drop-down lists of the cells of the table row, select the values of the port you are
configuring.
3. Click the "Set Values" button.
258

 E ven with half duplex, a point-to-point link is assumed.

 E ven with a full duplex connection, a point-to-point link is not assumed.
Note
Point-to-point link means a direct connection between two devices. A shared media
connection is, for example, a connection to a hub.
Point to point is calculated automatically. If the port is set to half duplex, a point-to-
point link is not assumed.
Shows that a point-to-point link exists.
Shows that no point-to-point link exists
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08