Appendix D
D.1 Messages in the event log
Messages
Fault state gone (reconfiguration): <fault description>
<fault description>:"Link down on P1." "Link up on P1."
"Power down on line L1 (L2)".
Fault state: <fault description> cleared.
<fault description>:"Warm start performed" "Cold start per-
formed".
Messages about MSTP
Messages
Spanning Tree: topology change detected.
Spanning Tree: new root bridge xx:xx:xx:xx:xx:xx
detected.
Messages about security
Messages
RADIUS: Access accepted / rejected for client
<MAC>.
Messages about message system
Messages
Syslog-Server not reachable!
Unable to send messages to syslog server.
Please check syslog socket configuration.
Unable to send e-mail(s) because of IP connec-
tion failure.
Unable to send e-mail(s) because of SMTP au-
thentication failure.
Unable to send e-mail(s) because SMTP mes-
sage transfer failed.
SNMP: Authentification failure.
IP communication is possible. Remote logging
activated.
IP communication is not possible. Remote log-
ging deactivated. Please check IP configuration
and network connectivity.
312
Description
Outgoing fault.
The event was triggered due to a change in the configura-
tion.
Fault was acknowledged by the user.
Description
You enable or disable the "Spanning Tree" event in "System > Events"
The topology of the network has changed; the network will be reor-
ganized.
The topology of the network has changed; there is a new root bridge
with MAC address xx:xx:xx:xx:xx:xx in the network.
Description
The authentication of the client was successful or not successful.
Description
The configured Syslog server is not accessible.
The syslog server configuration is incomplete.
Sending of e-mail(s) failed. SMTP server cannot be reached (e.g. net-
work connection interrupted).
Sending of e-mail(s) failed. Authentication of the client on the SMTP
server incorrect.
Sending of e-mail(s) failed. SMTP server can be reached, configuration
incomplete or contains errors (e.g. receiver e-mail address wrong /
does not exist).
Authentication of an SNMP client failed; access not possible (e.g.
SNMPv1/v2 read-only configured or Read Community String incorrectly
configured).
IP communication is possible. Remote logging is activated.
IP communication is not possible. Remote logging is deactivated.
Check whether or not the device has an IP address.
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08