Packet Error - Siemens SCALANCE W780 Configuration Manual

Simatic net industrial wireless lan to ieee 802.11n web based management
Hide thumbs Also See for SCALANCE W780:
Table of Contents

Advertisement

5.4.8.4

Packet Error

Bad received frames
This page shows how many bad frames were received per port. You cannot configure
anything on this page.
Description
The table has the following columns:
● Port
Shows the available ports.
● Error types
The other columns after the port number contain the absolute numbers of the incoming
frames according to their error type.
In the columns of the table, a distinction is made according to the following error types:
– 
 C RC
– 
 U ndersize
– Oversize
– 
 F ragments
– Jabbers
– Collisions
Description of the button
"Reset Counter" button
Click "Reset Counter" to reset all counters. The counters are also reset by a restart on the
device.
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
Packets whose content does not match the CRC checksum.
Packets with a length less than 64 bytes.
Packets discarded because they were too long.
Packets with a length less than 64 bytes and a bad CRC checksum.
VLAN-tagged packets with an incorrect CRC checksum that were discarded because
they were too long.

 D etected collisions.