2-12
Installing Your 1394 (applies to all systems)
Incorrect Shunt Placement
Top of cabinet
Publication 1394-5.0 — May 2000

Shunt Module Mounting Orientation

Because the shunt module dissipates excess regenerative power in the
form of heat, you need to consider the following guidelines. Refer to
Figure 2.11 and Figure 2.12 for shunt module spacing requirements.
Figure 2.11
Shunt Module Spacing Requirements Within an Enclosure
254 mm (10.0 in.) clearance
for airflow and installation
155 mm (6.1 in.) clearance
for airflow and installation
for signal, power and motor connections
155 mm (6.1 in.) clearance
for airflow and installation
Figure 2.12
Shunt Module Spacing Requirements Outside of an Enclosure
Solid protective plate
254 mm (10.0 in.) clearance
for airflow and installation
155 mm (6.1 in.) clearance
for airflow and installation
ALLEN-BRADLEY
BULLETIN 1394 3600W SHUNT MODULE
CAT.
INPUT DC
FOR FUSE REPLACEMENT USE:
BUSSMAN CAT. NO.
FOR USE WITH 1394-SJT22-X SYSTEM MODULE
Wire entry area
for signal, power and motor connections
155 mm (6.1 in.) clearance
for airflow and installation
Temperature sensitive component
(mounted above shunt module)
1394 Digital Servo Controller
3600W Shunt Module
155 mm (6.1 in.) clearance
for airflow and installation
ALLEN-BRADLEY
R
BULLETIN 1394 3600W SHUNT MODULE
CAT.
PART
SER.
INPUT DC
INPUT AC
FOR FUSE REPLACEMENT USE:
BUSSMAN CAT. NO.
FOR USE WITH 1394-SJT22-X SYSTEM MODULE
Wire entry area
1394 Digital Servo Controller
3600W Shunt Module
155 mm (6.1 in.) clearance
for airflow and installation
R
PART
SER.
INPUT AC
Enclosure