Overview
• Four power supplies are recommended if the power configuration for that chassis requires greater than
2500W or if using Cisco UCS Release 1.4(1) and later releases
• Two power supplies are recommended if the power configuration for that chassis requires less than
2500W or the system is using Cisco UCS Release 1.3(1) or earlier releases
Note
Both grids in a power redundant system should have the same number of power supplies. If your system is
configured for grid redundancy, slots 1 and 2 are assigned to grid 1 and slots 3 and 4 are assigned to grid 2.
If there are only two power supplies (PS) in the a redundant mode chassis, they should be in slots 1 and 3.