MASTER CONNECTION

The Master model includes a configurable set of input and outputs that have a specific
purpose and it depends on the selected topology and pin configuration.
Through the GUI, the user can choose the type of configuration. The operator must fol-
low the indications for the type of pin selected and the safety standards.
NOTE
NOTE

Master M12 8-Pole Connector

The Master M12 8-pole model has various pin typologies. The features of all the electri-
cal pins are showed in the chart below.
CATEGORY
INPUT/OUTPUT
SAFETY
OUTPUTS
The Multi In/Out is a Pin that can be configured either as input or output.
MULTI-OUT
Input and output connected to the Laser Sentinel must be aligned with the
features of the used pin.
8-pole and 12-pole connectors cannot be used together, but just individu-
ally according to application needs.
Figure 2 - Connector (M12, 8-pole Male)
TYPE
POWER SUPPLY
POWER
GND_ISO
MULTI IN
MULTI IN
MULTI IN/OUT
OSSD 1/1
OSSD 1/2
OTHER
F_EARTH
TYPE
MULTI-IN
OVERRIDE (Single line pattern)
OSSD
COLOR
DESCRIPTION
BROWN
BLUE
GREEN
Selectable by GUI
YELLOW
Selectable by GUI
WHITE
Selectable by GUI
GRAY
PINK
RED
FUNCTION
RESTART/RESET
AREA SWITCH
MUTING 1 MUTING 2
MUTING ENABLE
WARNING
MUTING LAMP
OSSD 1/1 OSSD 1/2
MASTER CONNECTION
PIN OUT
24Vdc
0 V
Safety Output
Safety Output
Functional Earth
CONNECTION
INSTRUCTION MANUAL
2
7
3
4
1
5
6
8
41