DIAGNOSTIC NOTES, WARNINGS, AND ERRORS

DISPLAYED
ICON
DLDNF
DLDNC
CLEANW2
ITLOCKx
INFT6
BOOTF
MUT TIMEOUT
MUTING ERR
MUTING
OVERRIDE ERR
DISPLAYED
DEVICE
FAULT CODE
STATUS
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
DIAGNOSTIC NOTES, WARNINGS, AND ERRORS
OSSD
DESCRIPTION
STATUS
OFF
Downloading new firmware.
OFF
Downloading new configuration.
It is suggested to clean the window
ON
to avoid entering lockout condition.
Interlock. Waiting for the relevant
OFF
OSSD pair to restart.
Micro integrity test failure. Internal
ON
peripheral test for non safety rele-
vant functions.
Invalid boot. Re-boot the system
until the normal condition is
OFF
restored. If warning persists, con-
tact Datalogic Technical Support.
Muting has expired because it is
ON
maintained beyond the maximum
timeout time.
Muting has not activated because
ON
the correct sequence was not fol-
lowed.
ON
The Muting function is active.
Override has not been activated
because the correct sequence has
ON
not been followed or there are no
override conditions.