MECHANICAL MOUNTING

ANGLE ADJUSTMENT BRACKET MOUNTING

First, provide two M5 holes with 73 mm spacing on the intended wall or mounting sur-
face.
NOTE

Pitch and Roll Angle Adjustment Bracket (SLS-BRACKET-A)

The bracket system (10) is partially assembled.
1. Mount the roll adjustment bracket (4) to the wall or panel by inserting two M5
2. After removing the M4 screws and washers (5) from the roll adjustment bracket
NOTE
30
SAFERY LASER SCANNER
The M5 UNI 5933 screws used for mounting the brackets to a wall are not
supplied in the SLS bracket mounting kits; they must be supplied by the
user.
UNI 5933 screws (not included), and tighten them, repeatedly alternating
between one and the other, until they are completely tight.
(4), use them to assemble the support bracket (10) to the roll adjustment bracket
(4).
Still, do not tighten the M4 Roll Adjustment screws for the roll angle (5).
Figure 4 - Pitch and Roll Angle Adjustment Bracket