The Laser Sentinel Stand Alone model has one OSSD pair and three signals programma-
ble as inputs and outputs. These signals allow the user to configure the device with sev-
eral functions:
NOTE
NOTE
CATEGORY
INPUT/OUTPUT
SAFETY
OUTPUTS
The Multi In/Out is a Pin that can be configured either as input or output.
MULTI-OUT
the detection of a person or an object in the Warning Zone,
the switching of the detection areas by employing external signals (Area Switch),
the restart of the device caused by the OSSD Off-status (Restart),
restoring the device after a failure condition (Reset),
the automatic deactivation of the safety status on the whole safety zone (Muting),
the Single line pattern Muting Override used to force the safety function deactiva-
tion whenever it is necessary to restart the machine.
For further information about the device functions, refer to Chapter 8,
Functions .
Make sure that the signals are aligned with the pin features and their spe-
cific function. In addition, they must be correctly connected to the external
device.
Figure 1 - Connector (M12, 8-pole Male)
TYPE
POWER SUPPLY
POWER
GND_ISO
MULTI IN/OUT
MULTI IN/OUT
MULTI IN/OUT
OSSD 1/1
OSSD 1/2
OTHER
F_EARTH
TYPE
MULTI-IN
OVERRIDE (Single line pattern)
OSSD
LASER SENTINEL STAND ALONE MODEL CONNECTORS
COLOR
DESCRIPTION
BROWN
BLUE
GREEN
Selectable by GUI
YELLOW
Selectable by GUI
WHITE
Selectable by GUI
GRAY
PINK
RED
FUNCTION
RESTART/RESET
AREA SWITCH
MUTING 1 MUTING 2
MUTING ENABLE
WARNING
MUTING LAMP
OSSD 1/1 OSSD 1/2
PIN OUT
24Vdc
0 V
Safety Output
Safety Output
Functional Earth
CONNECTION
INSTRUCTION MANUAL
2
7
3
4
1
5
6
8