Beckhoff AX8-1 Series Documentation page 19

Twinsafe drive option
Table of Contents

Advertisement

Wiring
Wires with ferrules with plastic collars must be used when using the STO safety function via
the STO inputs on X15 and X25.
Attention
5.2.4.2
Setting the TwinSAFE address
If a TwinSAFE connection is used instead of the digital inputs for the implementation of the safety functions
or selection of the STO function, a safety address must be set on the axis module.
This setting is made with the integrated DIP switch on the AX8000 axis module, which is located under the
cover between the X15 and X25 inputs or, in the case of single-axis modules, to the left of X15.
AX81xx-x1xx single-axis module
DIP switch
1
2
3
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
...
...
...
ON
ON
ON
TwinSAFE address
Each TwinSAFE address may only be used once within a network / a configuration!
The address 0 is not a valid TwinSAFE address!
WARNING
AX8911 - TwinSAFE Drive Option
4
5
6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
...
...
ON
ON
ON
Version: 1.0.0
AX82xx-x1xx dual-axis module
7
8
9
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
...
...
ON
ON
ON
Operation
Address
10
OFF
1
OFF
2
OFF
3
OFF
4
OFF
5
OFF
6
OFF
7
...
...
ON
1023
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax8911

Table of Contents