Bus Type, Address Selection And Function; Maintenance And Troubleshooting Leds - Bosch B426 Setup & Troubleshooting

Conettix ethernet communication module
Table of Contents

Advertisement

Bus Type, Address Selection and Function

Set the address switch to the correct position for the control panel SDI or Option Bus address using table 1
below.
Address Switch
Position
Bus/Address
SDI: Address Selected in
0
Browser
1
SDI 2: 1
2
SDI 2: 2
3
SDI: 80
4
SDI: 88
5
SDI: 92
6
Option Bus: 134
7
Option Bus: 13
8
Option Bus: 14
9
Option Bus: 250
Table 1 Panel Compatibility & Address Selection

Maintenance and troubleshooting LEDs

Use the Heartbeat (system status), RX (receive) and TX (transmit) LEDs to assist with troubleshooting:
Flash pattern
Flashes once every 1 sec
3 quick flashes every 1 sec
On Steady
Off
Table 2 Heartbeat LED descriptions
Compatible Control Panels
Select Panel address using web browser
GV4 & B-Series
GV4 & B-Series
GV4 Series, G – GV3 and any with firmware
version 6.0+
GV4 Series, G – GV3 and any with firmware
version 6.0+
GV4 Series, GV3 Series
FPD-7024, D7240v2, D7220v2, Easy Series 3+
DS7400xi
DS7400xi
FPD-7024
Function
Normal state. Indicates normal operation state.
Communication error state. Indicates a bus communication
error. The module is not receiving commands from the control
panel.
Trouble state. Indicates a trouble condition exists.
LED trouble state. Module is not powered, or some other trouble
condition prohibits the module from controlling the heartbeat
LED.
5
Operation
Determined by panel address selected
Remote Programming, Reporting or Automation
Remote Programming, Reporting or Automation
Automation
Remote Programming, or Reporting
Remote Programming, or Reporting
Reporting only
Remote Programming, or Reporting
Reporting
Remote Programming, or Reporting