FC 300 Operating Instructions
Control characteristics:
Resolution of output frequency at 0 - 1000 Hz .................... FC 301: +/- 0.013 Hz / FC 302: +/- 0.003 Hz
Repeat accuracy of Precise start/stop (terminals 18, 19) .......... FC 301: ≤ ± 1ms / FC 302: ≤ ± 0.1 msec
System response time (terminals 18, 19, 27, 29, 32, 33) .................. FC 301: ≤ 20 ms / FC 302: ≤ 2 ms
Speed control range (open loop) ............................................................... 1:100 of synchronous speed
Speed control range (closed loop) ........................................................... 1:1000 of synchronous speed
Speed accuracy (open loop) .................................................. 30 - 4000 rpm: Maximum error of ±8 rpm
Speed accuracy (closed loop) ............................................. 0 - 6000 rpm: Maximum error of ±0.15 rpm
All control characteristics are based on a 4-pole asynchronous motor
Surroundings:
Enclosure ............................................................................................................................... IP 20
Enclosure kit available ..................................................................................... IP21/TYPE 1/IP 4X top
Vibration test .......................................................................................................................... 1.0 g
Max. relative humidity ................... 5% - 95%(IEC 721-3-3; Class 3K3 (non-condensing) during operation
Aggressive environment (IEC 721-3-3), uncoated .................................................................
Aggressive environment (IEC 721-3-3), coated ....................................................................
Ambient temperature .................................................... Max. 50 °C (24-hour average maximum 45 °C)
Derating for high ambient temperature, see special conditions in the Design Guide
Minimum ambient temperature during full-scale operation ............................................................
Minimum ambient temperature at reduced performance ...........................................................
Temperature during storage/transport ........................................................................ -25 - +65/70 °C
Maximum altitude above sea level .......................................................................................... 1000 m
Derating for high altitude, see special conditions in the Design Guide
EMC standards, Emission ............................... EN 61800-3, EN 61000-6-3/4, EN 55011, (EN 50081-1/2)
EMC standards, Immunity ....................................................................
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, (EN 50082-1/2)
See section on special conditions in the Design Guide
Protection and Features:
Electronic thermal motor protection against overload.
Temperature monitoring of the heatsink ensures that the trips if the temperature reaches 95 °C ± 5°C.
An overload temperature cannot be reset until the temperature of the heatsink is below 70 °C ± 5°C.
The frequency converter is protected against short-circuits on motor terminals U, V, W.
If a mains phase is missing, the frequency converter trips or issues a warning.
Monitoring of the intermediate circuit voltage ensures that the frequency converter trips if the
intermediate circuit voltage is too low or too high.
The frequency converter is protected against earth faults on motor terminals U, V, W.
General Specifications
MG.33.A2.02 - VLT is a registered Danfoss trademark
class 3C2
class 3C3
- 10 °C
EN 61800-3, EN 61000-6-1/2,
0 °C
51