FC 300 Operating Instructions
16-** Data readouts
Par.
Parameter description
No. #
16-0* General status
16-00 Control Word
16-01 Reference [Unit]
16-02 Reference %
16-03 Status word
16-05 Main actual value [%]
16-1* Motor status
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor voltage
16-13 Frequency
16-14 Motor current
16-16 Torque
16-17 Speed [RPM]
16-18 Motor thermal
16-3* Drive status
16-30 DC link Voltage
16-32 Brake energy /s
16-33 Brake energy /2 min
16-34 Heatsink temp.
16-35 Inverter thermal
16-36 InomVLT
16-37 ImaxVLT
16-38 SL controller state
16-39 Controlcard temp.
16-5* Ref. & feedb.
16-50 External reference
16-51 Pulse reference
16-6* Inputs & outputs
16-60 Digital input
16-61 Terminal 53 switch setting
16-62 Analog input 53
16-63 Terminal 54 switch setting
16-64 Analog input 54
16-65 Analog output 42 [mA]
16-66 Digital output [bin]
16-67 Freq. input #29 [Hz]
16-68 Freq. input #33 [Hz]
16-69 Pulse output #27 [Hz]
16-70 Pulse output #29 [Hz]
16-8* Fieldbus & FC port
16-80 Fieldbus CTW 1
16-82 Fieldbus REF 1
16-84 Comm. option STW
16-85 FC port CTW 1
16-86 FC port REF 1
16-9* Diagnosis Readout
16-90 Alarm word
16-92 Warning word
16-94 Extended status word
*
default setting
( )
display text
46
How to Programme
Default value
0
0.000 Unit
0.0 %
0
0
0.0 kW
0.00 hp
0.0 V
0.0 Hz
0.00 A
0.0 Nm
0 RPM
0 %
0 V
0.000 kW
0.000 kW
0 °C
0 %
Drive dependent
Drive dependent
0
0 °C
0.0
0.0
0
[0] Current
0.000
[0] Current
0.000
0.000
0
0
0
0
0
0
0
0
0
0
0
0
0
[ ]
value for use in communication via serial communication port
MG.33.A2.02 - VLT is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Type
0
V2
-3
Int32
-1
Int16
0
V2
0
N2
2
Uint32
-2
Uint32
-1
Uint16
-1
Uint16
-2
Uint32
-1
Int16
67
Int32
0
Uint8
0
Uint16
0
Uint32
0
Uint32
100
Uint8
0
Uint8
-2
Uint16
-2
Uint16
0
Uint8
100
Uint8
-1
Int16
-1
Uint32
0
Uint16
-
Uint8
-3
Int32
-
Uint8
-3
Int32
-3
Int16
0
Int16
0
Int32
0
Int32
0
Int32
0
Int32
0
V2
0
N2
0
V2
0
V2
0
N2
0
Uint32
0
Uint32
0
Uint32