Danfoss VLT AutomationDrive FC 300 Operating Instructions Manual page 43

Hide thumbs Also See for VLT AutomationDrive FC 300:
Table of Contents

Advertisement

FC 300 Operating Instructions
9-** Profibus
Par.
Parameter description
No. #
9-00
Setpoint
9-07
Actual Value
9-15
PCD write configuration
9-16
PCD read configuration
9-18
Node address
9-22
Telegram selection
9-23
Parameters for signals
9-27
Parameter edit
9-28
Process control
9-53
Profibus Warning Word
9-63
Actual baud rate
9-64
Device Identification
9-65
Profile number
9-67
Control word 1
9-68
Status word 1
9-71
Save Data Values
9-72
Drive Reset
9-80
Defined parameters (1)
9-81
Defined parameters (2)
9-82
Defined parameters (3)
9-83
Defined parameters (4)
9-90
Changed parameters (1)
9-91
Changed parameters (2)
9-92
Changed parameters (3)
9-93
Changed parameters (4)
10-** CAN fieldbus
Par.
Parameter description
No. #
10-0* Common settings
10-00 CAN protocol
10-01 Baudrate select
10-02 MAC ID
10-05 Readout Transmit Error Counter
10-06 Readout Receive Error Counter
10-07 Readout Bus Off Counter
10-1* DeviceNet
10-10 Process data type selection
10-11 Process Data Config Write
10-12 Process Data Config Read
10-13 Warning Parameter
10-14 Net Reference
10-15 Net Control
10-2* COS filters
10-20 COS Filter 1
10-21 COS Filter 2
10-22 COS Filter 3
10-23 COS Filter 4
10-3* Parameter access
10-30 Parameter Data Types
10-31 Array index
10-39 Devicenet F parameters
*
default setting
( )
display text
How to Programme
Default value
0
0
0
0
126
[1] Standard telegram 1
0
[1] Enabled
[1] Enable cyclic master
0
[255] No baudrate found
0
0
0
0
[0] Off
[0] No action
0
0
0
0
0
0
0
0
Default value
[1] Device Net
[20] 125 Kbps
63
0
0
0
App. dependent
0
0
63
[0] Off
[0] Off
65535
65535
65535
65535
[0] Errata 1
0
0
[ ]
value for use in communication via serial communication port
MG.33.A2.02 - VLT is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
FALSE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
0
Uint16
0
Uint16
-
Uint16
-
Uint16
0
Uint8
-
Uint8
-
Uint16
-
Uint16
-
Uint8
0
V2
-
Uint8
0
Uint16
0
Uint8
0
V2
0
V2
-
Uint8
-
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
Type
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
0
Uint16
-
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
-
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
-
Uint8
0
Uint16
0
Uint32
43