FC 300 Operating Instructions
1-** Load/Motor
Par.
Parameter description
No. #
1-0* General settings
1-00
Configuration mode
1-01
Motor control principle
1-2* Motor data
1-20
Motor power [kW]
1-22
Motor voltage
1-23
Motor frequency
1-24
Motor current
1-25
Motor nominal speed
1-29
Automatic motor adaptation(AMA)
1-3* Advanced motor data
1-30
Stator resistance (Rs)
1-31
Rotor resistance (Rr)
1-33
Stator leakage reactance (X1)
1-34
Rotor leakage reactance (X2)
1-35
Main reactance (Xh)
1-36
Iron loss resistance (Rfe)
1-39
Motor poles
1-5* Load indep. setting
1-50
Motor magnetizing at zero speed
1-51
Min speed normal magnetizing [RPM]
1-6* Load depen. setting
1-60
Low speed load compensation
1-61
High speed load compensation
1-62
Slip compensation
1-63
Slip compensation time constant
1-64
Resonance dampening
1-65
Resonance dampening time constant
1-66
Min. current at low speed
1-67
Load type
1-68
Minimum inertia
1-69
Maximum inertia
1-7* Start adjustments
1-71
Start delay
1-72
Start function
1-74
Start speed [RPM]
1-76
Start current
1-8* Stop adjustments
1-80
Function at stop
1-81
Min speed for function at stop [RPM]
1-9* Motor temperature
1-90
Motor thermal protection
1-91
Motor external fan
1-93
Thermistor source
*
default setting
( )
display text
36
How to Programme
Default value
[0] Speed open loop
[1] VVCplus
Drive dependent
Drive dependent
Drive dependent
Drive dependent
Drive dependent
[0] Off
Motor dependent
Motor dependent
Motor dependent
Motor dependent
Motor dependent
Motor dependent
Motor dependent
100 %
1 RPM
100 %
100 %
100 %
0.10 s
100 %
5 ms
100 %
[0] Passive load
Drive dependent
Drive dependent
0.0 s
[2] Coast/delay time
0 RPM
0.00 A
[0] Coast
0 RPM
[0] No protection
[0] No
[0] None
[ ]
value for use in communication via serial communication port
MG.33.A2.02 - VLT is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
Type
-
Uint8
-
Uint8
1
Uint32
0
Uint16
0
Uint16
-2
Uint16
67
Uint16
-
Uint8
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-3
Uint32
0
Uint8
0
Uint16
67
Uint8
0
Int16
0
Int16
0
Int16
-2
Uint16
0
Uint16
-3
Uint8
0
Uint8
-
Uint8
-4
Uint32
-4
Uint32
-1
Uint8
-
Uint8
67
Uint16
-2
Uint16
-
Uint8
67
Uint16
-
Uint8
-
Uint16
-
Uint8