III. MAINTENANCE

1. User Maintenance
Refer to user manual for details.
1) List
No.
Location/Part
1
Main body
2
Feed path
3
Reading glass
4
Pressure board
5
Roller unit
6
Separation pad
2) Reading glass and pressure board
Where to clean is as follows.
Reading glass
For feeder
Figure 4-301
COPYRIGHT © 2006 CANON ELECTRONICS INC.
Item
Cleaning
Cleaning
Cleaning
Cleaning
Cleaning,
replacement
Cleaning,
replacement
Table 4-301
For flatbed
CANON DR-1210C FIRST EDITION FEB. 2006
CHAPTER 4 INSTALLATION & MAINTENANCE
Details
Wipe the surfaces with a cloth dipped into
water and wrung tightly, then wipe dry.
Using a blower, etc., remove dust and paper
powder from the document feed opening and
inside of the feeder.
Wipe with a clean and dry cloth. See section
2).
Remove the roller unit from the main body.
Wipe the surfaces with a cloth dipped into
water and wrung tightly, then wipe dry. The
roller unit and the separation pad are con-
sumable parts and the roller unit should be
replaced after an expected life of 100,000
sheets and the separation pad, 50,000 sheets.
See section 3).
Pressure board
Figure 4-302