Siruba Sew Reach ABF Series Instruction Book / Parts List page 53

Table of Contents

Advertisement

8.出 現錯 誤代 碼E48 : 夾 爪上釦 異 常
檢查夾爪上,是否
有鈕釦
YES
Check if there is
any button on the
clamp.
NO
以手動補釦或按下
手動補釦鈕補釦
Put the button
manually or by
press the manual
switch
9.出 現錯 誤代 碼E49 : 氣 源偵測 異 常
確認目前進氣總氣
源表是否為電子式
YES
錶頭
Confirm the
pressure gauge is
electronic table.
NO
機械錶頭無法加入
IN2的氣源壓力判
斷,故將H41參數設
定為0後,重新測試
If the mechanical is
unable to detect the
IN2 signal, set the
parameter H41 as
0and then test
again.
檢查I/O板上IN6位置訊
號線鬆脫?
Check If the IN6
position signal wire on
the I/O board is loose?
YES
重新接妥訊號線並檢查有
無接觸不良問題
Reconnect the signal
wire and check if there is
a problem of connection
檢查壓力開關的設定值
是否正確?
Check the pressure
switch settings are
correct?
NO
調整壓力開關設定值到正
確位置
Adjust the pressure
switch to the accurate
position.
-47-
8.Display the error code E48
clamp is abnormal.
檢查I/O板是否有
DC24V電壓?
NO
NO
Check if the
DC24V voltage is
in the I/O board.
YES
更換ABF機台內
控制基板
Replace with
another control
board in the ABF
machine
9.Display the error code E49
us detected abnormal
檢查I/O板上IN2位
置訊號線鬆脫?
YES
YES
Check If the IN2
position signal
wire on the I/O
board is loose?
NO
檢查I/O板是否有
DC24V電壓?
NO
Check if the
DC24V voltage is
in the I/O board.
YES
更換ABF機台內
控制基板
Replace with
another control
board in the ABF
machine
Introduction
The button
更換I/O板
後重新再測一次?
Substitute another
I/O panel and test
again.
The air supply
重新接妥訊號線並
檢查有無接觸不良
問題
Reconnect the
signal wire and
check if there is a
problem of
connection.
更換I/O板
後重新再測一次?
Substitute another
I/O panel and test
again.
P47