Siruba Sew Reach ABF Series Instruction Book / Parts List page 52

Table of Contents

Advertisement

5.出 現 錯 誤 代 碼E45 : 旋臂 逾 時未回 原 點
檢查磁簧開關安
裝位置是否正
確?
If the
installation of
the reef switch
is correct?
NO
調整磁簧開關
Adjust the reef
switch.
6.出現 錯誤 代碼E46 :ABF通 訊 故 障
檢查ABF控制基板是否有DC24V電壓?
Check if the DC24V voltage is in the ABF
control board.
更換ABF內之電源供應器後重新再測一次
Substitute another ABF switch power
and test again.
7.出現 錯誤 代碼E47 : 鈕 扣尺 寸不 符
確認人機面板上,鈕
扣的直徑尺寸
Confirmation of the
buttons diameter on
the operation panel
P46
進入參數A02檢查感測器是
否有亮滅反應或旋轉旋臂測
NO
試感測器上LED有無亮滅反
應?
Enter the parameter A02
detector to check if it can
work; check if the LED on
the sensor can be lit or
extinguished by test the
arm.
NO
檢查I/O板上IN3位置訊號線
鬆脫?
Check If the IN3 position
signal wire on the I/O board
is loose?
YES
接妥訊號線重新測試
Connect the signal wire
appropriately and test
again.
NO
確認H39參數, 是否符合目前鈕扣尺寸:
0:為小鈕釦Φ8-Φ16
1:為大鈕釦Φ16-Φ25
Confirm the H39 parameter:
0:for small buttons Φ8-Φ16
1:for large buttons Φ16-Φ25
調整H39參數
Adjust the H39 parameter
5.Display the error code E45
isn't back to the initial
檢查ABF控制基板
是否有DC24V電
YES
壓?
Check if the
DC24V voltage is
in the ABF
control board.
YES
更換ABF機台內控
制基板
Replace with
another control
board in the ABF
machine
6.Display the error code E46
communication of ABF is broken.
YES
NO 重新啟動再測一次
test again.
7.Display the error code E47
button is not applicable
NO
-46-
The rotary arm
檢查連接至主機之
訊號線或更換I/O板
NO
後重新再測一次.
Check the signal
wire connected to
the motherboard or
substitute the I/O
panel and test
again.
The
更換ABF內主機板
Substitute another ABF
motherboard
The size of
將鈕扣取出,重新量測
YES
鈕扣尺寸後,再測一次
Remove the buttons,
re-measure the buttons
size, and test again

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sew reach bt290-abf

Table of Contents