Chapter 1
Install the Cisco ONS 15310-MA SDH
NTP-H161 Preprovision an SFP Slot
Purpose
Tools/Equipment
Prerequisite Procedures

Required/As Needed

Onsite/Remote

Security Level

Complete the
Step 1
network.
Step 2
Click the Alarms tab and click Synchronize:
a.
b.
c.
In node view, double-click the 15310E-CTX-K9 card.
Step 3
Click the Provisioning > Pluggable Port Modules tabs.
Step 4
Step 5
In the Pluggable Port Modules pane, click Create. The Create PPM dialog box appears.
Step 6
In the Create PPM dialog box, complete the following:
Step 7
Click OK. The newly created port appears on the Pluggable Port Modules pane. The row on the
Pluggable Port Modules pane turns light blue and the Actual Equipment Type column lists the
preprovisioned PPM as unknown until the actual SFP is installed. After the SFP is installed, the row on
the pane turns white and the column lists the equipment name.
Verify that the PPM appears in the list on the Pluggable Port Modules pane. If it does not, repeat Steps
Step 8
through 7.
Repeat Steps
Step 9
Click OK.
Step 10
When you are ready to install the SFP, complete the
Step 11
page
Provision the Optical Line Rate" task on page
Stop. You have completed this procedure.
78-18668-01
This procedure preprovisions SFPs, which are referred to as pluggable port
modules (PPMs) in CTC. STM1, STM4, STM16, and multirate
(STM1/STM4/STM16) PPMs are compatible with the ONS 15310-MA
SDH. The SFP slots are located on the 15310E-CTX-K9 card.
None
Chapter 2, "Connect the PC and Log into the GUI"
As needed
Onsite or remote
Provisioning or higher
"DLP-H29 Log into CTC" task on page 16-43
Verify that the alarm filter is not turned on. See the
page 16-107
as necessary.
Verify that no unexplained conditions appear on the network. If unexplained conditions appear,
resolve them before continuing. Refer to the Cisco ONS 15310-MA SDH Troubleshooting Guide.
Complete the
"DLP-H223 Export CTC Data" task on page 18-20
information.
PPM—Click the slot number where the SFP is installed from the drop-down list.
PPM Type—Click the number of ports supported by your SFP from the drop-down list. If only one
port is supported, PPM (1 port) is the only option.
5
through
8
to provision a second PPM.
16-21. If you preprovisioned a multirate SFP, you must select the line rate using the
to log into an ONS 15310-MA SDH on the
"DLP-H88 Disable Alarm Filtering" task on
to export alarm and condition
"DLP-H16 Install SFP Connectors" task on
17-88.
Cisco ONS 15310-MA SDH Procedure Guide, R9.0
Required Tools and Equipment
"DLP-H193
1-31
5

Advertisement

Table of Contents
loading

Table of Contents