Cisco ONS 15310-MA SDH Procedure Manual page 25

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Chapter 1
Install the Cisco ONS 15310-MA SDH
Make sure you install the appropriate filler card for the slot where you are installing the card. Filler
Caution
card(s) for empty traffic card slots have the product ID 15310-EXP-FILLER, and filler cards for empty
15310E-CTX-K9 card slots have the product ID 15310-CTX-FILLER.
Open the card ejector at the top of the card.
Step 1
Slide the card along the guide rails into the slot.
Step 2
Close the ejector by firmly pushing it downward.
Step 3
Note
When you log into CTC, verify that the card appears properly in CTC node view.
Step 4
Continue with the
Step 5
procedure on page
Stop. You have completed this procedure.
NTP-H157 Install Wires to Alarm, Timing, Craft, LAN, and UDC
Pin Connections
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
78-18668-01
The filler cards are hot-pluggable, so they can be inserted or removed without turning off the
power to the ONS 15310-MA SDH.
"NTP-H157 Install Wires to Alarm, Timing, Craft, LAN, and UDC Pin Connections"
1-25.
This procedure installs alarm, timing, craft (for TL1), LAN (for CTC), and
UDC wires.
Alarm In cable, unshielded cable terminated with a DB-37 connector
Alarm Out cable, unshielded cable terminated with a DB-25 connector
Craft port serial cable, CAT-5 terminated with RJ-45
BITS timing port cable, CAT-3/CAT-5 terminated with DB-9 connector
Note
User data channel (UDC) cable: EIA/TIA-232 port cable, CAT-5
terminated with RJ-45
Management LAN cable, CAT-5 terminated with RJ-45
NTP-H150 Install the Shelf Assembly, page 1-5
As needed
Onsite
None
The cable shield must be wire-wrapped to the GND pin of the wire
wrap adapter.
Cisco ONS 15310-MA SDH Procedure Guide, R9.0
Required Tools and Equipment
1-25