Siemens RDG100KN Basic Documentation page 99

With knx communications
Hide thumbs Also See for RDG100KN:
Table of Contents

Advertisement

Name
Communications
P81
Device address
P82
Geographical zone (apartment)
P83
Geographical zone (room)
P84
Heat distr zone heating coil
P85
Refrig distr zone cooling coil
P86
Heat distr zone heating surface
P88
Transformation Precomfort
1)
Appl. = applications
3)
Physical address = Area.Line.DeviceAddress. Factory setting of Area = 0, Line = 2.
Can be changed by special management service, e.g. from line coupler or via ACS commissioning tool.
4)
Type = geographical zone A.R.S. In RDG sub zone = fixed value 1
Name
Diagnostics and test
d01
Application number
d02
X1 state
d03
X2 state
d04
D1 state
d05
Test mode for checking the Y1/Y2 actuator's running
direction
d06
Test mode for checking the Y3/Y4 actuator's running
direction
d07
Software version
d08
Test mode for checking the Q1 output (P72 function)
(RDG165KN)
d09
Test mode for checking the Q2 output (P73 function)
(RDG165KN)
d10
Test mode for checking the Q3 output (P74 function)
(RDG16...KN)
Siemens
Building Technologies
Factory setting
3)
255
4)
---
3)
1
---
---
---
0
5)
5)
5)
This parameter can only be quit when the setting is back at "---". Press the left button to escape
RDG100KN, RDG160KN, RDG165KN Basic Documentation
Range
1...255
---, 1...126
---, 1...63
---, 1...31
---, 1...31
---, 1...31
0 = Economy
1 = Comfort
Range
0 = (No application)
1 = 2-pipe
2 = 2-pipe with electric heater
3 = 2-pipe with radiator
4 = 4-pipe
5 = 2-stage heating or cooling
6 = 4-pipe with electric heater
"---" = Function not selected
0
= Not activated (for DI)
1
= Activated (DI)
0...49 °C = Current temp. value (for AI)
00
= H/C Input shorted
100
= H/C Input open
"---" = Function not selected
0
= Not activated (for DI)
1
= Activated (DI)
0...49 °C = Current temp. value (for AI)
00
= H/C Input shorted
100
= H/C Input open
"---" = Function not selected
0
= Not activated (for DI)
1
= Activated (DI)
00
= H/C Input shorted
100
= H/C Input open
"---" = No signal on outputs Y1 and Y2
OPE = Output Y1 forced opening
CLO = Output Y2 forced closing
"---" = No signal on outputs Y3 and Y4
OPE = Output Y3 forced opening
CLO = Output Y4 forced closing
Ux.xx is displayed
"---" = no signal at output Q1
OPE = output Q1 forced opening
CLO = output Q1 forced closing
"---" = no signal at output Q2
OPE = output Q2 forced opening
CLO = output Q2 forced closing
"---" = no signal at output Q3
OPE = output Q3 forced opening
CLO = output Q3 forced closing
1)
Appl
, P01
1)
Appl
, P01
1)
Appl
P46
P47
1)
P72, App
1)
P73, App
1)
P74, App
99 / 132