RDG/RDF – room thermostats
Application Guide
Answers for infrastructure.
Answers for infrastructure.

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RDG Series

  • Page 1 RDG/RDF – room thermostats Application Guide Answers for infrastructure. Answers for infrastructure.
  • Page 2 Application overview 4-pipe with Chilled/ el. heater heated ceiling 2-pipe Chilled/heated el. heater or ceiling with el. heater radiator Chilled/heated 2-pipe ceiling and radiator Fan coil unit Universal 2-stage Chilled heating ceiling or cooling and radiator Compressor Single duct for heating or cooling Variable air volume Heat pumps...
  • Page 3: Table Of Contents

    Contents Introduction ........................ 4 Before you start ......................4 Description of RDG range ................... 4 Product range RDG ....................4 Description of RDF.. semi fl ush-mount range ............... 5 Product range RDF/RDU stand-alone ................5 Product range RDF/RDU stand-alone with time program ..........5 Product range RDF/RDU with bus interface ..............5 Description of applications ..................
  • Page 4: Introduction

    Introduction The RDG and RDF thermostat range is very versatile and includes a number of products. RDG and RDF offer extensive features and cover a broad range of applications. The document: – provides you an overview of the new RDG and RDF ranges –...
  • Page 5: Description Of Rdf

    – RDG160 – the energy-effi cient modulating thermostat to control electronic commutated fan motors (ECM Fans), operating on AC 24 V (SELV) with DC 0...10 V outputs for valve and fan – RDG160KN – the communicating energy-effi cient modulating thermostat for control- ling electronic commutated fan motors (EC Fans) and either DC or 2-position valves, or for 3-speed fan and DC valves, including KNX interface –...
  • Page 6: Description Of Applications

    Description of applications The RDG/RDF thermostats cover the following applications: FCUs via ON/OFF or modulating control outputs: – 2-pipe system – 2-pipe system with electric heater – 2-pipe system and radiator/fl oor heating – 4-pipe system – 4-pipe system with electric heater –...
  • Page 7: Extensive Features And Functions

    Heat pumps with DX type equipment: – 1-stage compressor for heating or cooling – 1-stage compressor for heating or cooling with electric heater – 1-stage compressor for heating or cooling and radiator/fl oor heating – 1-stage compressor for heating and cooling with reversing valve –...
  • Page 8: Fan Coil - Application Overview

    Application description – Control sequences for heating and/or cooling, 1 or 2 stages – Multifunctional inputs for keycard contact, external sensor, etc. – Automatic or manual heating/cooling changeover – Automatic or manual fan speed – 3-speed, 1-speed and mod. (ECM) fan control (DC 0...10 V) –...
  • Page 9 RDG.. RDF.. Type of control outputs Application Wall-mounted range Semi fl ush-mounted range 2-pipe system and radiator heating 2-pipe (ON/OFF) and radiator (ON/OFF) RDG100.. RDG110 2-pipe (ON/OFF) and radiator (mod. PWM or 3-pos.) RDG100.. 2-pipe mod. (PWM) and radiator (ON/OFF, PWM or 3-pos.) RDG100..
  • Page 10: Fan Coil - Product Overview

    Fan coil – product overview Stand-alone with Application Stand-alone Communicating Product 7-day program Communicating RDG100… – 2-pipe (ON/OFF, PWM or 3-pos.) RDG100 RDG100T RDG100KN – 2-pipe with electric heater RDG100T/H (KNX) Versatile thermostats with – FCU: (ON/OFF, PWM or 3-pos.) control output signal (ON/OFF) –...
  • Page 11 Stand-alone with Application Stand-alone Communicating Product 7-day program Semi fl ush-mounted units: RDF RDF300.. – 2-pipe RDF300.. RDF301.. – FCU: (ON/OFF or 3-pos.) (KNX) Versatile thermostats with – 2-pipe (ON/OFF) with el. heater (ON/OFF) RDF302 – 4-pipe (ON/OFF) relay ouputs: ON/OFF or 3-pos. (ModBus) RDF310../410..* –...
  • Page 12: Universal - Application Overview

    Application description – For heating and/or cooling applications with heated/chilled ceiling or radiator – Control sequences for heating and/or cooling, 1- or 2-stages – Dew point monitoring – Multifunctional inputs for keycard contact, external sensor, etc. – Automatic or manual heating/cooling changeover Universal –...
  • Page 13 RDG… Application Type of control outputs Wall-mounted range Chilled/heated ceiling and radiator Chilled/heated ceiling (ON/OFF) and radiator (ON/OFF) RDG100.. RDG110 Chilled/heated ceiling (ON/OFF) and radiator (mod. PWM or 3-pos.) RDG100.. Chilled/heated ceiling, mod. (PWM) and radiator (ON/OFF, PWM or 3-pos.) RDG100..
  • Page 14: Universal - Product Overview

    Universal – product overview Stand-alone with Product Application Stand-alone Communicating 7-day program Wall-mounted units: RDG RDG100… – Chilled/heated ceiling (ON/OFF, PWM or 3-pos.) RDG100 RDG100T RDG100KN – Chilled/heated ceiling and el. heater (KNX) Versatile thermostats – CLC: (ON/OFF, PWM or 3-pos.) with control outputs –...
  • Page 15: Heat Pumps - Application Overview

    Application description – Control sequences for heating and/or cooling, 1- or 2-stage – Dew point monitoring – Multifunctional inputs for keycard, contact, external sensor, etc. – Min. ON/OFF time for compressor short cycle protection Heat pumps – application overview RDG.. RDF..
  • Page 16 RDG.. RDF.. Type of control outputs Application Wall-mounted range Semi fl ush-mounted range Compressor in DX-type equipment heating and cooling 1-stage compressor (ON/OFF) for heating and cooling RDG110 RDG160KN RDF300.. RDF600.. 1-stage compressor (ON/OFF) for heating and cooling RDG110 with reversing valve Compressor in DX-type equipment, cooling or heating, 2-stage 2-stage compressor (ON/OFF) for heating or cooling RDG110...
  • Page 17: Heat Pumps - Product Overview

    Heat pumps – product overview Stand-alone with Product Application Stand-alone Communicating 7-day program Wall-mounted units: RDG RDG110 – 1-stage compressor (ON/OFF) for heating or cooling RDG110 – 1-stage compressor (ON/OFF), with el. heater (ON/OFF) Thermostat with relay output – 1-stage compressor (ON/OFF) for heating and cooling (SPDT) to ON/OFF control –...
  • Page 18: Vav - Application Overview

    Application description – Control sequences for heating and/or cooling – Modulating control output DC 0…10 V or 3-pos. for VAV box/air fl ow controller – Multifunctional inputs for keycard, contact, external sensor, etc. – Automatic or manual heating/cooling changeover – Adjustable minimum and maximum limitation of air fl...
  • Page 19: Vav - Product Overview

    RDG.. RDF.. Type of control outputs Application Wall-mounted range Semi fl ush-mounted range Single duct with radiator Single duct (DC 0...10 V) for VAV-box RDG400.. with radiator (ON/OFF) Single duct (DC 0...10 V) for VAV-box RDG400.. with radiator (mod. PWM or 3-pos.) Single duct (3-pos.) for VAV-box RDG400..
  • Page 20: How To Prepare And Set Up Your Room Thermostats

    How to prepare and set up your room thermostats Introduction The versatile RDG and RDF room thermostats help you to better meet your customer‘s needs. The following information supports you in setting up your RDG and RDF thermostats. Control parameters A number of control parameters can be adjusted to optimize control performance and enable additional functions, making it possible to employ.
  • Page 21: Application-Specifi C Parameters

    Application-specifi c parameter Control sequence (P01) This parameter is used to set the required heating and/or cooling sequence and to select automatic/manual changeover. Parameter P01 is preset as follow, depending on the selected application: – 2-pipe or single-duct application: P01: = 1 = cooling only –...
  • Page 22: Communicating, Knx Thermostats

    Fan function RDG and RDF offer an extensive fan control concept with a wide choice of functions and (P03, P52...P62, P67): features. The required options can be selected via the control parameters: – Fan mode automatic-manual or manual only (P03) –...
  • Page 23: Faq

    Where are the DIP switches located? On RDG, the DIP switches are located at the rear of the unit; on RDF semi fl ush-mount thermostats, they are located on the inner side of the front panel. Where do I fi nd the correct DIP switch position? Refer to the Mounting Instructions and on the product.
  • Page 24: Application Examples

    Application examples Installation and set up 1. Select a suitable thermostat. 2. Set application via DIP switch according to the mounting Instructions. 3. Wire and install the thermostat. Apply power. 4. If necessary, set parameter P01 (control sequence) and other application-specifi c parameters. Fan coil application Application How to set the application...
  • Page 25 Application How to set the application FCU, 2-pipe and fl oor heating, single speed 1. Thermostat: RDG100 2. DIP switch: 2-pipe application and radiator Y1 = ON/OFF Y3 = ON/OFF Actuator cooling → Y1-N 3. Wiring: Actuator heating → à Y3-N Fan →...
  • Page 26 VAV application examples Application How to set the application VAV single duct, cooling only 1. Thermostat: RDG400 2. DIP switch: Single duct application Y10 = DC 0...10 V Actuator → Y10-Go-G 3. Wiring: Window contact → D1-GND 4. Parameters: no change (= default) –...
  • Page 27 Notes...
  • Page 28 The required features should therefore be specified in each individual case at the time of closing the contract. © Siemens Switzerland Ltd, 2013 • Order no. 0-92173-en • 0,71306 Answers for infrastructure.