Chapter 8 Parameters

P1-xx Basic Parameters

P1-00▲
PTT
Parameter
Attribute:
Operational
Interface:
Default: 0x2
Control
Mode:
Unit: -
Range: 0 ~ 0x1142
Data Size: 16bit
Format: HEX
Settings:
Pulse Type
0: AB phase pulse (4x)
1: Clockwise (CW) and Counterclockwise (CCW) pulse
2: Pulse + symbol
Other setting: reserved
Filter Width
If the received frequency is much higher than the setting, it will be
regarded as the noise and filtered out.
Setting
Value
8-38
The Type of External Pulse Input
Parameter for individual axis
Panel / Software
PT
Low-speed filter
frequency
(Min. pulse width*
0
0.83Mpps (600ns)
1
208Kpps (2.4us)
2
104Kpps (4.8us)
3
52Kpps (9.6us)
4
No filter function
Communication
Setting
Value
(Min. pulse width*
)
note1
0
3.33Mpps (150ns)
1
0.83Mpps (600ns)
2
3
4
ASDA-M
Address: 0100H
0101H
Related Section:
Section 6.2.1
High-speed filter
frequency
)
note1
416Kpps (1.2us)
208Kpps (2.4us)
No filter function