ASDA-M
3.3.3 Wiring Diagram (CN1)
The valid voltage of speed analog command and torque analog command is between
-10V and +10V. The command value can be set via relevant parameters. The input
impedance is 10K.
C1: speed, Input of Torque Analog Command
C2:Analog Monitor Output MON1 ,MON2
Revision December, 2014
Servo Drive
24kΩ
MON1 16
(MON2 15)
GND
13
SG
_ +
Max.
8V
output 1mA
8kΩ
8V full scale
Chapter 3 Wiring
3-31