ASDA-B2

P1-xx Basic Parameters

P1-00▲
PTT
Operation
Interface:
Default: 0x2
Control
Mode:
Range: 0 ~ 1142
Data Size: 16-bit
Format: Hexadecimal
Settings:
Pulse type
0: AB phase pulse (4x)
1: Clockwise (CW) + Counterclockwise (CCW) pulse
2: Pulse + Symbol
Other settings: reserved
Filter width
If the filter pulse frequency is too high instantaneously, the pulse
frequency exceeding the frequency setting will be filtered out as noise.
Setting
Value
Revision May, 2018
External Pulse Input Type
Panel/Software
PT
Unit: -
Minimum Pulse Width
(Low-speed Filter Frequency
*note 1
0
600 ns (0.83 Mpps)
1
2.4 us (208 Kpps)
2
4.8 us (104 Kpps)
3
9.6 us (52 Kpps)
4
No Filter Function
Communication
Setting
Value
)
0
1
2
3
4
Chapter 7 Parameters
Address: 0100H
0101H
Related Section:
6.2.1
Minimum Pulse Width
(High-speed Filter
*note 1
Frequency
)
150 ns (3.33 Mpps)
600 ns (0.83 Mpps)
1.2 us (416 Kpps)
2.4 us (208 Kpps)
No Filter Function